{"id":714,"date":"2026-06-24T14:09:28","date_gmt":"2026-06-24T06:09:28","guid":{"rendered":"https:\/\/wangyuanele.com\/?post_type=product&#038;p=714"},"modified":"2026-07-10T13:37:11","modified_gmt":"2026-07-10T05:37:11","slug":"post-type-disconnector-series","status":"publish","type":"product","link":"https:\/\/wangyuanele.com\/index.php\/product\/post-type-disconnector-series\/","title":{"rendered":"Post-type Disconnector Series"},"content":{"rendered":"<h2>Product Description<\/h2>\n<p>WANGYUAN Post-type Disconnector are designed for visible circuit isolation on overhead distribution lines and substations. Made of high-strength ceramic insulators or composite silicone rubber with hot-dip galvanized steel frames and copper alloy contacts, the robust blade-type switching mechanism ensures reliable make-break operation under load conditions. Available in single-phase and three-phase configurations with manual or motorized actuation, all products comply with relevant international standards, widely deployed in utility pole-mounted and substation isolation applications.<\/p>\n<h2>Specification<\/h2>\n<h3>Pole mounted air breaker switch without fuse<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-724 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.webp\" alt=\"\" width=\"900\" height=\"252\" srcset=\"\/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.webp 900w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse-300x84.webp 300w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse-768x215.webp 768w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse-600x168.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"72\">Type<\/td>\n<td width=\"72\">L<\/td>\n<td width=\"72\">W<\/td>\n<td width=\"72\">H<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">(H)GW-12(15)<\/td>\n<td width=\"72\">1530<\/td>\n<td width=\"72\">675<\/td>\n<td width=\"72\">730<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">(H)GW-24(27)<\/td>\n<td width=\"72\">1730<\/td>\n<td width=\"72\">750<\/td>\n<td width=\"72\">860<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">(H)GW-30(36)<\/td>\n<td width=\"72\">1885<\/td>\n<td width=\"72\">820<\/td>\n<td width=\"72\">990<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-725 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.2.webp\" alt=\"\" width=\"900\" height=\"291\" srcset=\"\/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.2.webp 900w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.2-300x97.webp 300w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.2-768x248.webp 768w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-air-breaker-switch-without-fuse.2-600x194.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"72\">Type<\/td>\n<td width=\"72\">L<\/td>\n<td width=\"72\">W<\/td>\n<td width=\"72\">H<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">(H)RGW-12(15)<\/td>\n<td width=\"72\">1530<\/td>\n<td width=\"72\">675<\/td>\n<td width=\"72\">1510<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">(H)RW-24(27)<\/td>\n<td width=\"72\">1730<\/td>\n<td width=\"72\">750<\/td>\n<td width=\"72\">1510<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">(H)RGW-30(36)<\/td>\n<td width=\"72\">1885<\/td>\n<td width=\"72\">820<\/td>\n<td width=\"72\">1510<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Pole-mounted lACM Volley Disconnector<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-726 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Pole-mounted-lACM-Volley-Disconnector.webp\" alt=\"\" width=\"900\" height=\"450\" srcset=\"\/wp-content\/uploads\/2026\/06\/Pole-mounted-lACM-Volley-Disconnector.webp 900w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-lACM-Volley-Disconnector-300x150.webp 300w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-lACM-Volley-Disconnector-768x384.webp 768w, \/wp-content\/uploads\/2026\/06\/Pole-mounted-lACM-Volley-Disconnector-600x300.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/p>\n<p>Technical characteristics<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"128\">Item<\/td>\n<td width=\"104\">Unit<\/td>\n<td colspan=\"3\" width=\"322\">Data<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated voltage<\/td>\n<td width=\"104\">kV<\/td>\n<td width=\"104\">12<\/td>\n<td width=\"108\">24<\/td>\n<td width=\"108\">36<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated frequency<\/td>\n<td width=\"104\">Hz<\/td>\n<td colspan=\"3\" width=\"322\">50\/60<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated current<\/td>\n<td width=\"104\">A<\/td>\n<td colspan=\"3\" width=\"322\">100\/200\/400<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated short-circuit withstand\/ breaking current<\/td>\n<td width=\"104\">kA<\/td>\n<td colspan=\"3\" width=\"322\">12.5<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated short-circuit making current (peak)<\/td>\n<td width=\"104\">kA<\/td>\n<td colspan=\"3\" width=\"322\">32<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated peak withstand current<\/td>\n<td width=\"104\">kA<\/td>\n<td colspan=\"3\" width=\"322\">32<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Rated short-circuit time<\/td>\n<td width=\"104\">Sec<\/td>\n<td colspan=\"3\" width=\"322\">1<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Mechanical Operations<\/td>\n<td width=\"104\">Times<\/td>\n<td colspan=\"3\" width=\"322\">5000<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Power frequency withstand voltage (1 min)<\/td>\n<td width=\"104\">kV<\/td>\n<td width=\"104\">28\/32<\/td>\n<td width=\"108\">50\/60<\/td>\n<td width=\"108\">70\/80<\/td>\n<\/tr>\n<tr>\n<td width=\"128\">Lightning impulse withstand voltage (peak)<\/td>\n<td width=\"104\">kV<\/td>\n<td width=\"104\">76\/85<\/td>\n<td width=\"108\">125\/145<\/td>\n<td width=\"108\">170\/195<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Pole-mounted Load Breaker Switch<\/h3>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"219\">Item<\/td>\n<td width=\"82\">Unit<\/td>\n<td colspan=\"3\" width=\"246\">Data<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\" width=\"104\">For active circuits<\/td>\n<td width=\"115\">20breakings<\/td>\n<td rowspan=\"8\" width=\"82\">A<\/td>\n<td width=\"82\">630<\/td>\n<td width=\"82\">630<\/td>\n<td width=\"82\">400<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">30breakings<\/td>\n<td width=\"82\">400<\/td>\n<td width=\"82\">400<\/td>\n<td width=\"82\">300<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">40breakings<\/td>\n<td width=\"82\">300<\/td>\n<td width=\"82\">300<\/td>\n<td width=\"82\">250<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">50breakings<\/td>\n<td width=\"82\">250<\/td>\n<td width=\"82\">250<\/td>\n<td width=\"82\">170<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">75breakings<\/td>\n<td width=\"82\">170<\/td>\n<td width=\"82\">170<\/td>\n<td width=\"82\">160<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">120breakings<\/td>\n<td width=\"82\">110<\/td>\n<td width=\"82\">110<\/td>\n<td width=\"82\">110<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">200breakings<\/td>\n<td width=\"82\">65<\/td>\n<td width=\"82\">65<\/td>\n<td width=\"82\">65<\/td>\n<\/tr>\n<tr>\n<td width=\"115\">280breakings<\/td>\n<td width=\"82\">50<\/td>\n<td width=\"82\">50<\/td>\n<td width=\"82\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">For ring circuits<\/td>\n<td width=\"115\"><\/td>\n<td width=\"82\">A<\/td>\n<td width=\"82\">630<\/td>\n<td width=\"82\">400<\/td>\n<td width=\"82\">250<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">Rated breaking capacity of transformer<\/td>\n<td width=\"115\"><\/td>\n<td width=\"82\">A<\/td>\n<td colspan=\"3\" width=\"246\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">Rated breaking capacity of cable charging<\/td>\n<td width=\"115\"><\/td>\n<td width=\"82\">A<\/td>\n<td colspan=\"3\" width=\"246\">11<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">Rated breaking capacity of earthing fault<\/td>\n<td width=\"115\"><\/td>\n<td width=\"82\">A<\/td>\n<td colspan=\"3\" width=\"246\">56<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: The LBS type on load break switch (Switch disconnector) is equipped with stored energy released by fuse strike pins.<br \/>\nThe stored energy mechanism for the opening oparation is released by fuse strike pins.<br \/>\nThe trip actuator is mounted on top of the fuse contact clip.<br \/>\nThe DIN type fuse is held in spring type contacts, secured by a tailever. All the components are made of stainless steel, to preventcorrosion have Jong live, and in the rest position. The trip lever is parked in an over-centre position.<\/p>\n<h3>Outline Dimension<\/h3>\n<p>Electric parameter:<br \/>\nRated voltage: 12kV-24kV-36kV<br \/>\nRated current: 630A-1250A<br \/>\nPower frequency withstand: 42\/65\/95kV<br \/>\nLighting impulse withstand voltage: 95\/150\/215kV<br \/>\nShort circuit withstand: 20\/25kA<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-730 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Outline-Dimension.webp\" alt=\"\" width=\"900\" height=\"372\" srcset=\"\/wp-content\/uploads\/2026\/06\/Outline-Dimension.webp 900w, \/wp-content\/uploads\/2026\/06\/Outline-Dimension-300x124.webp 300w, \/wp-content\/uploads\/2026\/06\/Outline-Dimension-768x317.webp 768w, \/wp-content\/uploads\/2026\/06\/Outline-Dimension-600x248.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"72\">Type<\/td>\n<td width=\"72\">C<\/td>\n<td width=\"72\">D<\/td>\n<td width=\"72\">F<\/td>\n<td width=\"72\">H<\/td>\n<td width=\"72\">L<\/td>\n<td width=\"72\">W<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">LBS-12<\/td>\n<td width=\"72\">800<\/td>\n<td width=\"72\">1080<\/td>\n<td width=\"72\">1200<\/td>\n<td width=\"72\">670<\/td>\n<td width=\"72\">775<\/td>\n<td width=\"72\">1100<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">LBS-24<\/td>\n<td width=\"72\">900<\/td>\n<td width=\"72\">1180<\/td>\n<td width=\"72\">1200<\/td>\n<td width=\"72\">770<\/td>\n<td width=\"72\">450<\/td>\n<td width=\"72\">1400<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">LBS-36<\/td>\n<td width=\"72\">1000<\/td>\n<td width=\"72\">1280<\/td>\n<td width=\"72\">1200<\/td>\n<td width=\"72\">870<\/td>\n<td width=\"72\">700<\/td>\n<td width=\"72\">1900<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Advantages<\/h2>\n    <div class=\"single-product-advantages\">\n                    <article class=\"single-product-advantage\">\n                <div class=\"single-product-advantage__icon\">\n                                            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Isolation-Performance.webp\" alt=\"Isolation Performance\" loading=\"lazy\">\n                                    <\/div>\n                <h3>Isolation Performance<\/h3>\n                <p>The visible break blade design provides clear open\/closed position indication for operational safety. High-quality copper alloy contacts with wiping action ensure low contact resistance and reliable current transfer.<\/p>\n            <\/article>\n                    <article class=\"single-product-advantage\">\n                <div class=\"single-product-advantage__icon\">\n                                            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/06\/Easy-Installation-Maintenance.webp\" alt=\"Mechanical Strength\" loading=\"lazy\">\n                                    <\/div>\n                <h3>Mechanical Strength<\/h3>\n                <p>Hot-dip galvanized steel frames and mounting brackets withstand severe mechanical loads and short-circuit forces. Ceramic insulators offer high compressive and cantilever strength for long-term structural integrity on poles.<\/p>\n            <\/article>\n                    <article class=\"single-product-advantage\">\n                <div class=\"single-product-advantage__icon\">\n                                            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/05\/Waterproof-Safe.1.webp\" alt=\"Weather Resistance\" loading=\"lazy\">\n                                    <\/div>\n                <h3>Weather Resistance<\/h3>\n                <p>Ceramic insulators with glazed surface resist tracking, erosion and UV degradation in outdoor environments. Hot-dip galvanized steel components provide decades of corrosion protection in harsh climatic conditions.<\/p>\n            <\/article>\n                    <article class=\"single-product-advantage\">\n                <div class=\"single-product-advantage__icon\">\n                                            <img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/05\/4-5.webp\" alt=\"Installation &amp; Range\" loading=\"lazy\">\n                                    <\/div>\n                <h3>Installation &amp; Range<\/h3>\n                <p>Compact post-type design simplifies pole mounting with standard bracket interfaces. Motorized actuator option enables remote SCADA-controlled operation, supporting both single-phase and three-phase line configurations.<\/p>\n            <\/article>\n            <\/div>\n    \n<h2>Use scenario diagram<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-720 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-1-1.webp\" alt=\"\" width=\"900\" height=\"1203\" srcset=\"\/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-1-1.webp 900w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-1-1-224x300.webp 224w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-1-1-766x1024.webp 766w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-1-1-768x1027.webp 768w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-1-1-600x802.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-722 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-2-1.webp\" alt=\"\" width=\"900\" height=\"1350\" srcset=\"\/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-2-1.webp 900w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-2-1-200x300.webp 200w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-2-1-683x1024.webp 683w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-2-1-768x1152.webp 768w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-2-1-600x900.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-721 aligncenter\" src=\"\/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-3-1.webp\" alt=\"\" width=\"900\" height=\"1350\" srcset=\"\/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-3-1.webp 900w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-3-1-200x300.webp 200w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-3-1-683x1024.webp 683w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-3-1-768x1152.webp 768w, \/wp-content\/uploads\/2026\/06\/Use-scenario-diagram.1-3-1-600x900.webp 600w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Post-type disconnectors offer reliable visible circuit isolation for overhead lines and substations, with manual or motorized single-phase and three-phase configurations.<\/p>\n","protected":false},"featured_media":715,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[19],"product_tag":[],"class_list":["post-714","product","type-product","status-publish","has-post-thumbnail","product_cat-insulator-and-arrester","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/product\/714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/comments?post=714"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/media\/715"}],"wp:attachment":[{"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/media?parent=714"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=714"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=714"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/wangyuanele.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}